CopperSilver Lab Essay Research Paper Gayle AdkinsonDirector

Copper/Silver Lab Essay, Research Paper

Gayle Adkinson

Director of Operations

Adkinson Chemical Corporation

Dear Mrs. Adkinson:

A sample of copper has been produced as requested. We are pleased to report that the

most copper has been produced through the most efficient method. But we regrettably to

report that an accident had occurred during the process (which you will not be billed for).

This accident led to a series of investigations to weed out incompetent workers. The

remaining technicians were the best and most capable of producing the highest purity of

copper at the minimum cost. Captain Copper Chemical Corporation supplies

application-specific process chemicals for most of the science industry. The combination

of high technology products and in-depth support, from the technical service team, allows

the customer to maximize productivity and minimize cost. Captain Copper Chemical

Corporation is a technology-driven, not marketing-driven company. We pride ourselves

on our capacity to solve client?s chemical process issues, and will develop custom

products, when required. Captain Copper Corporation is currently both the leading North

American distributor of chemicals and a world leader in manufacturing a variety of

chemical specialties. In locations throughout the world, you?ll find Captain Copper

Chemical Corporation operations upholding standards that keep safety, health and

environmental considerations a top priority. OSHA has deemed the CCCC of using safe

techniques and proper disposal of wastes. CCCC strives to be the most dependable

supplier of high-quality goods and services for our important constituents. CCCC is

dedicated into achieving mutually profitable relationships with our customers and suppliers

by providing quality products and services, on time and consistently, and by remaining

constantly aware of changing customer needs. Captain Chemical Corporation invites you

to share your chemical process problems, and issues, so that we may offer and

demonstrate our capacity to assist you in becoming the leader in your industry.

Procedure

Day 1

1.Determine limiting reactant

2. Prepare a data table with the following: mass of- beaker A, beaker B, beaker A +

CuSO4 . 5H2O, beaker B + Fe, CuSO4 . 5H2O , Fe, filter paper, beaker B + filter

paper + Cu, Cu, and observations

3.Clean and dry two 250 mL beakers. Label one A and the other B. Mass each

beaker. Record results in data table

4.Purchase 10g of CuSO4 . 5H2O and 2.22g of Fe (less than needed to make sure all

Fe reacts). Place CuSO4 . 5H2O in beaker A and Fe in beaker B. Mass each

beaker. Record results in data table

5.Dissolve CuSO4 . 5H2O (Dr. Merck informed us that CuSO4 . 5H2O was soluble)

6.Heat beaker A (w/ CuSO4 . 5H2O (aq)). Heat until solution is hot but not boiling.

7.Remove beaker A from hot plate using beaker tongs and pour CuSO4 . 5H2O (aq)

into beaker A and let CuSO4 . 5H2O react with Fe

8.Let the chemicals react. Done for the day.

Day 2

9.Make observations of solution and precipitate.

10.Setup to filter solution. Set ring stand with funnel. Mass filter paper. Record

results in data table. Fold filter paper and set it up in funnel. Wet filter paper to

remove all space between filter paper and funnel.

11.Decant solution and filter into beaker A using stirring rod. Rinse precipitate (Cu)

with distilled water. Filter solution again. Do this about three times.

12.Dispose of filtrate (FeSO4). Place filter paper into beaker B with precipitate. Dry

beaker B. Done for the day.

Day 3

13.Make observations of copper. Scrape any remaining copper on filter paper into

beaker. Mass the copper and record results into data table (Dr. Merck

recommends removing all iron impurities with a magnet)

Data Table

The following calculations were made prior to the lab for limiting reactant determination

to make efficient use of all materials.

molar mass of CuSO4 . 5H2O = 63.5g Cu + 32.1g S + 144.0g O + 10.1g H = 249.7g

molar mass of Fe = 55.8g

molar mass of FeSO4 = 55.8g Fe + 32.1g S + 64.0g O = 151.9g FeSO4

molar mass of Cu = 63.5g Cu

mols of 10g CuSO4 . 5H2O

= 0.040048058 mols of CuSO4 . 5H2O

mols of 10g Fe

= 0.17921147

mols of Fe needed if 10g CuSO4 . 5H2O

mols of CuSO4 . 5H2O if 10g Fe

mass of Fe needed if 10g of CuSO4 . 5H2O is used:

= 2.234681618g Fe = 2.23g Fe

mass of CuSO4 . 5H2O needed if 10g of Fe is used:

= 44.74910394g CuSO4 = 44.7g

CuSO4

* mass of CuSO4 . 5H2O

CuSO4 . 5H2O is the limiting reactant.

mass of Cu expected to be produced from 2.22g of Fe:

= 2.526344086g Cu = 2.53g Cu

The following calculation was made after the lab for percent yield determination:

2.50g Cu (actual mass)

2.53 g Cu (theoretical mass) x 100 = 98.8142292% = 99%

99% of the theoretical mass of copper to be produced was retrieved.

Materials

CuSO4 . 5H2O.5 grams = $.5010g = $10.00

Fe.5 grams = $1.002.22g x 2= $8.88

Total$18.88




Не сдавайте скачаную работу преподавателю!
Данный реферат Вы можете использовать для подготовки курсовых проектов.

Поделись с друзьями, за репост + 100 мильонов к студенческой карме :

Пишем реферат самостоятельно:
! Как писать рефераты
Практические рекомендации по написанию студенческих рефератов.
! План реферата Краткий список разделов, отражающий структура и порядок работы над будующим рефератом.
! Введение реферата Вводная часть работы, в которой отражается цель и обозначается список задач.
! Заключение реферата В заключении подводятся итоги, описывается была ли достигнута поставленная цель, каковы результаты.
! Оформление рефератов Методические рекомендации по грамотному оформлению работы по ГОСТ.

Читайте также:
Виды рефератов Какими бывают рефераты по своему назначению и структуре.