Реферат по предмету "На английском языке"


Acetylation Of Ferrocene Essay Research Paper Acetylation

Acetylation Of Ferrocene Essay, Research Paper
Acetylation of Ferrocene
17. October 1996
Experiment #7
Introduction
In this lab we will be utilizing the Friedel Crafts process of
acetylation of ferrocene. Ferrocene is an atom of iron bounded by two aromatic
rings. We will use some reagents that will cause the ferrocene to add either
one acetyl group to an aromatic ring or add two acetyl groups to each of the
aromatic rings. In order to determine how well this process had worked we
employed: IR spectra analysis, column chromatography, and a little TLC. This
experiment is relevant in today’s highly industrialized world. By utilizing
many of the techniques we employ in this lab, a company can synthesize new types
of materials or composites that could revolutionize an industry.
Background
When we react the ferrocene with phosphoric acid and acetic anhydride,
we obtain many disparate products. Not only do we get acetylferrocene, but we
also get diacetylferrocene, some unreacted ferrocene reactant, and acetic acid
as well. We will use thin layer chromatography (TLC), column chromatography
(CG), and IR spectra analysis in order to determine the what proportions of
each of these compounds will be present in the final product.
Both TLC and CG are excellent methods of measuring the presence of a
given substance. Both methods turn around a compounds polarity. As one recalls,
polarity is a measure of the electronegativity of a compound determined by their
placement in the periodic chart. Specifically, in this lab we are talking about
the difference in polarity between the atoms of oxygen and carbon. Ferrocene is
relatively low to none in polarity. Acetylferrocene, because of the carbonyl
functional group, is more polar than the ferrocene. Moreover, diacetylferrocene,
because of the 2:1 ratio of the carbonyl groups over the acetylferrocene, is the
most polar of the lot.
As stated above, both TLC and CG take advantage of polarity. Both
methods have an extremely polar stationary phase; specifically, silica or
alumina gel is used. Through this polar stationary phase, a mobile liquid phase
is passed. Now, one can think of a polar stationary phase as a bully that waits
in the high school halls for his hooligan friends. His hooligan friends,
hooley’s as I like to call them, always stay back to talk him; the rest of the
normal student body simply keep walking and pass him. The idea here is: like-
stays-with- like. Analogously, those compounds which are most similar to the
stationary substrate will stay behind to “hang out”. In this case, the more
polar the compound is, then the more it will stay behind as the rest of the
product moves forward in its liquid mobile phase. TLC works by capillary action,
where the mobile phase is drawn up the TLC plate and across a polar TLC plate.
CG, on the other hand, works by having gravity pull the liquid mobile phase
down a polar laden column. The joyous wonder of TLC and CG, then, is that they
are thus able to separate each constituent contained in the product.
Methods & Procedure
The procedure of for this lab may be found in the pre-lab note for this
experiment contained in the appendix. I will only remark on the important
features of the procedure. The amount of start material for this lab was ca. 10
g. The calculation for this may also be found in the pre-lab I first added
acetic anhydride to ferrocene (FC) and then warmed to add in the H3PO4
catalyst. I observed a reddish-violet color to this mix of reactants. I then
did a TLC and noted that the majority of the sample was not the original
ferrocene start material. Please see the pre-lab for reproductions of the TLC
plates used in this lab. Also see table 1.2 for Rf values.
As one can see, this crude’s Rf is half that of the start material.
This indicates that a reaction has definitely occurred. Next we performed an
extraction on this sample with Methylene Chloride (MeCl) and Sodium Hydroxide
(OH-). Please see the pre-lab for a picture of what the extraction looked like.
Then we transferred the lower organic potion into another vial with a little
sodium sulfate for drying. Then we transferred this to a tarred vial and dried
off the MeCl in a nitrogen stream. MeCl is a great solvent because it
evaporates easily (bp. ca. 48?C). Moreover, we used a nitrogen steam so that we
could minimize the amount of moisture in regular air from being reintroduced
into the sample. This was our second crude sample and we did a TLC on it with
FC start material. See Tables 1.1 and 1.2 for amount of crude sample obtained
and the Rf values. We allowed this to dry over till next weekend; we then
performed a CG on this sample.
We placed this crude into the CG and then added three mobile solvents to
it in order to separate the crude. We used Hexane (non-polar), Ethyl Acetate
(medium polarity) and Methanol (Nice and polar). The sample flowed down the
column and into separate tarred vials for each colored material. The first was
bright yellow. The second was a deep reddish color. The third was a dark
violet. I placed each vial into the N2 stream for concentration and then re-
weighed each sample, called F1, F2, F3, respectively, again. The results are
presented in table 1.1 at the end of the next section. After yet another class
lab on this experiment, I tried to take 5 mg of each sample and place it into
K-Br for IR spectra. However, after waiting till the next period for the IR,
hardly any of the materials we present in each vial. This was quite
inexplicable. I did manage to get melt-temps, but I was only able to scrape
together enough of the F2 for IR spectra. See the appendix for the results of
the IR spectra and see table 1.3 for the melt temp values.
I also took a TLC on each one as well; the values are presented in
table 1.2 at the end of the next section.
Results & Observations
The results of this experiment are pretty straight forward and are
summarized in tables 1.1 through 1.3 in this section.
Table 1.1 Weights and Measures
F1F2F3 DRAM Vial
Weight:4.648012.191412.2362 Vial &
Mix:4.687112.217712.2439 Amount Present in
grams:0.003910.002360.0077
in mg:3.91 mg2.36 mg7.7 mg 1
The next table revolves around TLC results
Table 1.2 TLC Rf Values
First CrudeSecond CrudeFC MixAFC
MixDAFCMix Spot A: .38 .43, .84
.67.54, .75 .61 Spot B: .75
.84 .74 .77
.36 Cospot A/B:.38, .75 .43, .84 .74
.77.36, .88 2
The melt-temp values are:
Table 1.3 Melt-Temp Values
F1 F2 F3
Sample Melt-Temp:195-200?C90-94?C75-80?C
Actual Melt-Temp:173?C85-86?C130-131?
C 3
The IR spectra may be found in the appendix.
Discussion
From the first crude sample’s TLC that was taken, one can see that
roughly half of the material present is composed of acetylferrocene and
diacetylferrocene. Thus we continued along in the procedures. The results of
the CG, which was performed next separated the constituent products enough that
more TLC’s were able top be taken. The results of these TLC Rf’s tell us that
our separation was pretty successful. As one can see, F1 spot A’s Rf, we have
at least 90% of FC in separated mixture. This is great. It means the
extraction was a success. The F2 percent difference is 2.7%. This means that
over 97% of this material are indeed AFC. OUTSTANDING results. This was a
success for, one of the very few in this lab; thus, I am quite happy. The
percent difference for the DAFC, however, is quite disappointing. Only 30 % of
this mix is indeed DAFC. This is not that good of a separation. The reasons
for this are explainable though. I believe it is due to inaccurate CG technique.
I did not wait for all of the AFC to finish flowing out of the column before I
placed the vial down to obtain the DAFC. Thus, as the TLC shows, most of this
material is not DAFC. I think from comparison Rf’s to the AFC TLC plates that
it is probably AFC; this does then confirm that its probably the AFC. Moreover,
it also could be some acetic alcohol as well. If this was a side-product formed.
After all, acetic alcohol is quite polar; thus it would be one of the last
products out along with the DAFC. Table 1.4 shows the calculations.
Table 1.4 Percent Different Calculations 4 F1 %D = Actual – Start Material x
100
Start Material
= 0.67 – 0.74 x 100 = 9.97%
.74 F2 %D = Actual – Start Material x 100
Start Material
= 0..75 – 0.77 x 100 = 2.65%
.77 F3 %D = Actual – Start Material x 100
Start Material
= 0.61 – 0.36 x 100 = 69.5%
.36 5
The IR spectra for F2 show us that we have mostly AFC formed. The peak
at the 1700 range indicates that c=o bonds are present in this sample. AFC does
indeed have the carbonyl bound present. Furthermore, since the size of the peak
indicated the amounts of c=o bonds present, we would expect it to be a smaller
peak than a F3 IR for DAFC. But I do not have an IR for F3 for comparison.
Nevertheless, it probably has a big peak there in proportion to the F2 anyway.
Hmmmmm. A large peak around the 2900 mark indicates the present of a hydrogen
bonded to an aromatic ring. Our IR spectra for F2 does indeed show a peak in
this range. So we conclude that this sample is acetylferrocene.
Conclusions
In sum, this lab was successful. It taught us how to correctly test the
accuracy of a synthesis reaction; specifically, the acetylation of ferrocene.
Our results show us the accurately synthesized and separated out the ferrocene
and acetylferrocene from the reaction. The separation of the diacetylferrocene
was not as successful as the extraction of the other two, but an explanation for
this seems superficially valid.


Не сдавайте скачаную работу преподавателю!
Данный реферат Вы можете использовать для подготовки курсовых проектов.

Поделись с друзьями, за репост + 100 мильонов к студенческой карме :

Пишем реферат самостоятельно:
! Как писать рефераты
Практические рекомендации по написанию студенческих рефератов.
! План реферата Краткий список разделов, отражающий структура и порядок работы над будующим рефератом.
! Введение реферата Вводная часть работы, в которой отражается цель и обозначается список задач.
! Заключение реферата В заключении подводятся итоги, описывается была ли достигнута поставленная цель, каковы результаты.
! Оформление рефератов Методические рекомендации по грамотному оформлению работы по ГОСТ.

Читайте также:
Виды рефератов Какими бывают рефераты по своему назначению и структуре.

Сейчас смотрят :